<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-15 02-41-15
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 49 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.4 kHz 69 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 62 kHz 19180 0,2450
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 1,63 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 2:41, 15.12.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 62 kHz MIN: 11 kHz % above 76 kHz: 0,2450 Acquired: 2025/12/15 2.40.10 Total samples: 19180 Equivalent time: 0:15:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,7 dBr MIN: 0,5 dBr AVE: 1,63 dBr % above 12,2 dBr: 0,0 Last value: 3,7 dBr (2025/12/15 2.40.10) 02.26 02.28 02.30 02.32 02.34 02.36 02.38 02.40 0 2 4 Pm [dBr]